Geyserwise Accredited Installations Specialist Vaal Triangle

Express Drains and Plumbing is an accredited Geyserwise installer serving the Vaal Triangle and surrounding areas. Geyserwise offers the most efficient and cost-effective solution for reducing your water heating expenses. Beyond saving you money, Geyserwise provides you with the ability to control and monitor your geyser, even when it’s hidden away in your roof, ensuring optimal performance and convenience.

Geyserwise Vaal Triangle

For use in pumped solar water heating systems

Description

Use as a geyser timer

Clear display of water temperature, time, day, heating mode and malfunction conditions.

Auto or manual heating.

Easy temperature setting to your requirements (30 - 65°C) factory default is 55°C.

Four different temperature settings.

Daily programmable timer with four time settings.

Error conditions alert by warning code E1 to E7.

Electronic thermostat with mechanical thermal cut-out at 90°C.

CONTACT 078 314 7309
FOR MORE INFO

CONTACT 078 314 7309
FOR MORE INFO

Use as timer on a thermosyphon solar system

Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.

Auto or manual heating.

Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.

Four different temperature settings.

Daily programmable timer with four time settings.

Error conditions alert by warning code E1 to E7.

Electronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for solar systems expected to reach temperatures above this temperature.

Use as timer and differential control on pumped solar system

Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.

Auto or manual heating.

Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C.

Four different temperature settings.

Daily programmable timer with four time settings.

Error conditions alert by warning code E1 to E9.

Electronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for systems expected to reach temperatures above this temperature.

Differential controller 12V and 220V systems.

Technical Parameters

Operating voltage 230VAC / 50HZ.

Main Relay contact rating 30AMP (Max 4KW).

Secondary relays pump and solenoid 5Amp.

Operating voltage range 160V – 250V AC.

Earth leakage protection at 25MA action time = 0,1 second.

Temperature display range 0 - 99°C (“-5” when below -5°C “EA” when above 99°C).

High temperature warning above 84°C.

Temperature setting ranges 30 - 65°C (heating water electrically).

Heat failure – when increase at a rate of less than 4°C per hour.

Electronic thermostat with mechanical thermal cut-out at 90°C.

Dry heat detection – empty cylinder.

Temperature tolerance ± 2%.

Temperature differential setting 1°C.

Switching differential 6°C.

2nd temperature probe for solar.

Solar differential 7°C.

Temperature probe failure detection for both collector and tank.

Temperature probe range for geyser is -30 to + 130°C.

Isolate both L + N when in off state.

Collector antifreeze protection at 5°C

how to set the system:
WATCH VIDEO WITH SETTINGS

Geyserwise Accredited Installations Specialist Vaal Triangle FAQs

Maximize your energy savings and gain complete control over your home’s water heating with Geyserwise, the leading solution for efficient and cost-effective geyser management. As an accredited installer serving the Vaal Triangle and surrounding areas, Express Drains and Plumbing offers expert installation, seamless integration with solar systems, and ongoing support to ensure your system operates at peak efficiency. Don’t miss out on the opportunity to reduce your utility bills and enhance your home’s energy efficiency—contact us today for a free consultation and experience the unmatched benefits of Geyserwise.

How can Geyserwise installations help reduce my water heating expenses?

Geyserwise systems are designed to optimize the efficiency of your water heating, significantly reducing your energy consumption and lowering your utility bills. By allowing precise control over your geyser’s operation, you can avoid unnecessary heating and ensure that your system operates only when needed, saving you money in the long run.

What is the advantage of controlling and monitoring my geyser remotely?

The ability to control and monitor your geyser remotely is a game-changer in home management. Whether your geyser is tucked away in the roof or elsewhere, Geyserwise gives you real-time access to its status and settings. This not only provides peace of mind but also allows you to adjust the system for optimal performance, even when you’re not at home.

Is Geyserwise compatible with both thermosyphon and pumped solar water heating systems?

Yes, Geyserwise is fully compatible with both thermosyphon and pumped solar water heating systems. Whether you are using a passive or active solar heating system, Geyserwise integrates seamlessly, offering you enhanced control, efficiency, and energy savings.

How does a Geyserwise timer improve the efficiency of my geyser?

The Geyserwise timer is a critical tool for maximizing your geyser’s efficiency. By scheduling the operation of your geyser, the timer ensures that water is heated only when necessary, preventing unnecessary energy consumption. This smart control leads to lower electricity usage and reduced costs without compromising on comfort.

What areas do Express Drains and Plumbing service for Geyserwise installations?

Express Drains and Plumbing proudly serves the Vaal Triangle and surrounding areas, including Vereeniging and Meyerton. As an accredited Geyserwise installer, we ensure that homeowners in these regions receive expert installation and support for their Geyserwise systems.

Can I get a free consultation and estimate for a Geyserwise installation?

Absolutely. We offer a free consultation and estimate to all potential customers. This allows you to understand the benefits of a Geyserwise system and receive a tailored solution that meets your specific needs, with no obligation.

How does the differential control feature work on a pumped solar system?

The differential control feature of the Geyserwise system is designed to optimize the performance of pumped solar systems. It monitors the temperature difference between the solar collector and the water in your geyser, activating the pump only when necessary. This ensures maximum efficiency, as the pump operates only when there is a significant gain in solar energy, reducing wear and energy usage.

Why should I choose an accredited Geyserwise installer?

Choosing an accredited Geyserwise installer like Express Drains and Plumbing ensures that you receive top-quality service and installation. Accreditation means that our technicians are fully trained and experienced in installing and maintaining Geyserwise systems, providing you with the confidence that your system will be installed correctly and perform as expected.

How long does the installation process take, and what can I expect?

The installation of a Geyserwise system is typically straightforward and can be completed within a few hours, depending on the complexity of your existing setup. Our team of experts will handle the entire process with minimal disruption to your home, ensuring that your new system is up and running efficiently in no time.

What kind of support and maintenance is available after installation?

After your Geyserwise system is installed, Express Drains and Plumbing provides ongoing support and maintenance to ensure optimal performance. Whether you need regular check-ups, adjustments, or have any concerns, our team is always available to assist, giving you peace of mind that your investment is protected.

Get A Free Consultation & Estimate

Fill in the form below with your message and we will respond shortly